All specimens are clamped individually in the specimen holders of the flammability tester (par. 4.2.2), with the staple on top and the stapled end at the closed end of the holder. They are then dried in a horizontal position in an oven for 30 minutes... Flammable Fabrics: Hearing...S. 2918 - 27 ÆäÀÌÁöÀúÀÚ: United States. Congress. Senate. Comm. on interstate and foreign commerce - 1952 - 61 ÆäÀÌÁöÀüüº¸±â - µµ¼ Á¤º¸
| 1997 - 762 ÆäÀÌÁö
...individually in the specimen holders of the flammability tester (paragraph (b)(3) of this section), with the staple on top and the stapled end at the...until cool, but for not less than 15 minutes. NAP WITH NAP AGAINST NAP BASE TABRIC FIGURE 4 — Lay of nap (g) Procedure for testing flammability. (1)... | |
| 1998 - 902 ÆäÀÌÁö
...individually in the specimen holders of the flammability tester (paragraph (b)(3) of this section), with the staple on top and the stapled end at the...calcium chloride in a desiccator until cool, but for not lees than 15 minutes. AGAINST NAP FIGURE 4—LAY OF NAP (g) Procedure for testing flammability. (1)... | |
| 1993 - 750 ÆäÀÌÁö
...individually in the specimen holders of the flammability tester (paragraph (b)(3) of this section), with the staple on top and the stapled end at the...position in an oven for 30 minutes at 221¡Æ F (105¡Æ ¬³), removed from the oven, and placed over anhydrous calcium chloride in a desiccator until cool,... | |
| 1978 - 690 ÆäÀÌÁö
...individually in the specimen holders of the flammability tester (paragraph (b)(3) of this section), with the staple on top and the stapled end at the...horizontal position in an oven for 30 minutes at 221¡Æ P (105¡Æ C), removed from the oven, and placed over anhydrous calcium chloride in a desiccator until... | |
| 2000 - 850 ÆäÀÌÁö
...individually in the specimen holders of the flammablllty tester (paragraph (b)(3) of this section), with the staple on top and the stapled end at the...horizontal position in an oven for 30 minutes at 221 ¡ÆP (105 ¡ÆC), removed from the oven, and placed over anhydrous calcium chloride in a desiccator until... | |
| United States. Congress. Senate. Committee on Commerce - 1952 - 2238 ÆäÀÌÁö
...of the bath shall be 30 times the weight of the swatches and the temperature shall be between 05¡Æ and 100¡Æ F. The swatches shall then be rinsed twice...than 15 minutes. Nap Base fabric With nap Against nap FIOUBE 4. Lay of nap 4.7 Procedure for testing flammabilily. 4.7.1 Adjust the position of the rack... | |
| United States. Congress. Senate. Committee on Interstate and Foreign Commerce - 1952 - 72 ÆäÀÌÁö
...then cut out as described in paragraph 4.1.5 and tested as described in paragraphs 4.6 and 4.7 4.6 Brushing and drying specimens. — Each specimen having...nap FIGURE 4. Lay of nap 4.7 Procedure for testing flammability. 4.7.1 Adjust the position of the rack of the flammability tester (par. 4.2) with a holder... | |
| United States. Congress. House. Committee on Interstate and Foreign Commerce - 1953 - 218 ÆäÀÌÁö
...orginal condition or after dry cleaning and washing, is placed on the brushing device carriage (paragraph 4.3) and drawn under the brush once against the lay...of the holder. They are then dried in a horizontal • The soap shall be made by dissolving 56 g. of caustic potash (KOH) in 100 ml. of water. The potassium... | |
| United States. Congress. House. Committee on Interstate and Foreign Commerce - 1953 - 216 ÆäÀÌÁö
...condition or after dry cleaning- and washing, is placed on the brushing device carriage (paragraph 4.3) and drawn under the brush once against the lay...of the holder. They are then dried in a horizontal • The soap shall be made by dissolving 56 g. of caustic potash (KOH) In 100 ml. of water. The potassium... | |
| 1977 - 380 ÆäÀÌÁö
...individually in the specimen holders of the flammability tester (paragraph (b) (3) of this section) , with the staple on top and the stapled end at the...horizontal position in an oven for 30 minutes at 221¡Æ F (103¡Æ ¬³), removed from the oven, and placed over anhydrous calcium chloride in a desiccator until... | |
| |