The Code of Federal Regulations of the United States of AmericaU.S. Government Printing Office, 1957 The Code of Federal Regulations is the codification of the general and permanent rules published in the Federal Register by the executive departments and agencies of the Federal Government. |
도서 본문에서
100개의 결과 중 1 - 5개
29 페이지
... exceed 16 ounces ) . 73.212 . No exemption , 73.193 ..... Trinitrobenzoic acid , dry . See High explosives . Trinitrobenzoic acid , wet , not ex- ceeding 16 ounces . Trinitrobenzoic acid , wet with not less than 10 percent water , in ex ...
... exceed 16 ounces ) . 73.212 . No exemption , 73.193 ..... Trinitrobenzoic acid , dry . See High explosives . Trinitrobenzoic acid , wet , not ex- ceeding 16 ounces . Trinitrobenzoic acid , wet with not less than 10 percent water , in ex ...
48 페이지
... exceed that passed by a No. 54 drill size opening are not required to be equipped with excess - flow valves . ( 1 ) Excess - flow valves shall close au- tomatically at the rated flows of gas or liquid as specified by the valve manu ...
... exceed that passed by a No. 54 drill size opening are not required to be equipped with excess - flow valves . ( 1 ) Excess - flow valves shall close au- tomatically at the rated flows of gas or liquid as specified by the valve manu ...
60 페이지
... exceed 150 grains . Blasting caps ( see Note 5 ) which have been provided with a means for firing by an electric current , and sealed , are known as electric blasting caps . ( 1 ) Detonating primers are devices for commercial use which ...
... exceed 150 grains . Blasting caps ( see Note 5 ) which have been provided with a means for firing by an electric current , and sealed , are known as electric blasting caps . ( 1 ) Detonating primers are devices for commercial use which ...
63 페이지
... exceed 150 pounds . ( b ) Each outside package must be plainly marked " AMMUNITION FOR SMALL ARMS WITH EXPLOSIVE BULLETS " or " AMMUNITION FOR SMALL ARMS WITH EXPLOSIVE PROJECTILES , " as the case may be . ( c ) Ammunition for small ...
... exceed 150 pounds . ( b ) Each outside package must be plainly marked " AMMUNITION FOR SMALL ARMS WITH EXPLOSIVE BULLETS " or " AMMUNITION FOR SMALL ARMS WITH EXPLOSIVE PROJECTILES , " as the case may be . ( c ) Ammunition for small ...
64 페이지
... exceed 75 pounds . ( 6 ) Spec . 12H , 23F , or 23H ( § 78.209 , § 78.214 , or § 78.219 of this chapter ) . Fiberboard boxes with inside cylindrical fiber cartridges not over 5 inches diam- eter nor over 18 inches long with fiber at ...
... exceed 75 pounds . ( 6 ) Spec . 12H , 23F , or 23H ( § 78.209 , § 78.214 , or § 78.219 of this chapter ) . Fiberboard boxes with inside cylindrical fiber cartridges not over 5 inches diam- eter nor over 18 inches long with fiber at ...
기타 출판본 - 모두 보기
자주 나오는 단어 및 구문
acid amended by Order approved attached Authorized gross weight barrels or drums blasting caps bottom brazing Bureau of Explosives carboys carrier certify chap chapter cleats closed closure comply containers as follows corrugated fiberboard cushioned cylinders dangerous articles devices Dichlorodifluoromethane dome exceed exemption fiberboard boxes flammable flange gallons capacity gauge length head heat hydrostatic test Inches Inches Inches inside containers label leakage less liquefied petroleum gas liquid loaded manway mark specified material ments Metal barrels minimum thickness motor vehicle nails nitroglycerin Order 27 package packed in specification paragraph percent placards plate plosives plug Poison pounds per square prescribed projectiles rail express rated capacity retested riveted Rolling hoops sealing device seams securely sheets shell shipments shipped side solid Spec specification containers specimen square inch steel tainers tank cars tare weight tensile strength test pressure threads tion trichlorosilane vent welded Wooden boxes yield strength
인기 인용구
372 페이지 - When the average value of the three specimens equals or exceeds the minimum value permitted for a single specimen and the value for more than one specimen is below the required average value, or when the value for one specimen is below the minimum value permitted for a single specimen, a retest of three additional specimens shall be made. The value of each of these retest specimens shall equal or exceed the required average value. When an erratic result is caused by a defective specimen, or there...